UTILITIES ENGINEERING

Maquire Road/Turnpike Utility Improvments  

Maguire Road/Turnpike Utility Improvements
City of Ocoee, Florida

DRMP provided utility improvements due to Turnpike widening including 252 LF 12” DR-18 PVC force main, 323 LF 12" DR-11 HDPE force main carrier piping with 323 LF 18” DR-11 HDPE casing piping both directionally drilled under the Turnpike, two (2) 12” line stops,  removal of 455 LF of existing 12” PVC force main piping, removal of 435 LF 12” PVC water main piping, removal of 310 LF of existing 30” steel casings from beneath the existing pavement limits, and filling existing steel casings with flowable fill.

Project Photo (click for larger view)
 
             

 

 

Existing Sewer System Evaluation at Coleman Federal Corrections Complex
KZF Design Studio

DRMP is responsible for 596-lot subdivision including 8,038 LF 8” PVC water main and 12,304 LF of 6” PVC water main hydraulically modeled using WaterGEMS and manifolded lift station modeling using SewerCAD for 2-20 hp Flygt duplex lift stations with 4,620 LF of 8” force main piping and 130 LF of 10” HDPE FM piping directionally drilled for tie-in to existing 12” FM, FDEP wastewater permitting and certifications, and coordination with Brevard County for ownership of lift stations.

Project Photos (click for larger view)
 
           

 

Osceola Parkway Utility Improvements  

Osceola Parkway Phase 1 Utility Improvements
Osceola County, Florida

DRMP was responsible for utility system improvements due to roadway widening including 7,600 LF of 24” DIP water main piping, 40 LF 16” DIP water main piping, 35 LF of 12" DIP water main piping, 11 LF of 12” PVC water main piping, 639 LF of 8" DIP water main piping, 11 LF of 6" DIP water main piping, 115 LF of DR-18 PVC water main piping, 219 LF of 4” DR-18 PVC water main piping, 776 LF of 36” steel casing jacked and bored with 776 LF of 24” DIP water main carrier pipe under the Florida Turnpike ROW, 144 LF 8” DR-18 force main piping, one 16” linestop, one 12” linestop, four 8” linestops, removal of approximately 5,945 LF of existing 12” PVC water main and 1,294 LF of existing 8” PVC water main piping, reconnections to existing water main services, coordination with Osceola County,  FDEP water permitting and certifications, FDOT Utility permitting for the Turnpike crossing, Construction Administration and bid assistance services.  The water main shall be owned, operated and maintained by Toho Water Authority (TWA).

 

Project Photo (click for larger view)
 
             

 

 

CR 470 Water Main Extension
Sumter County, Florida

DRMP designed the water distribution system including hydraulic modeling for this water main extension project that included 17,000 LF of 12-inch water main used along CR 470, CR 529, CR 527A and CR 527B.  The project allows the City of Bushnell to better employ their existing water treatment plant by providing water service to more customers, while economic incentive is provided for potential growth along CR 470, which has access to both the Turnpike and I-75. Even though the client requested an additional 4,000 LF of water main along CR 527 during the final design phase, DRMP staff was able to complete the design within the established project schedule. Permitting was required with the FDEP and FDOT.  Survey services and SUE were required to identify and map over three miles of utility corridor.

Project Photo (click for larger view)
 
             

 

 

Lake Panasoffkee Wastewater Study Update
Sumter County, Florida

DRMP staff updated a study previously prepared by DRMP in 1994 to determine the feasibility of constructing a wastewater collection and transmission system along the CR 470 corridor that connects to the City of Bushnell’s wastewater treatment plant.  The proposed wastewater system will service the Lake Panasoffkee community and help to maintain the water quality of the lake by removal of septic systems.  A map of the existing systems along CR 470 was prepared to determine the core commercial areas to be served along CR 470.  DRMP conducted two public information meetings with the community to first solicit feedback on the approach and then to present the initial finding of the report. 

Project Photo (click for larger view)
 
             

 

 

EXPLORE OUR SERVICES

 

 
 
Orlando Civil Engineering
0
     
 

CONSTRUCTION SERVICES

DESIGN-BUILD

ECOLOGICAL SERVICES

GENERAL CIVIL ENGINEERING

GEOGRAPHIC INFORMATION SYSTEMS (GIS)

STRUCTURAL ENGINEERING

SUBSURFACE UTILITY ENGINEERING (SUE)

SURVEYING & MAPPING / GEOMATICS

TRANSPORTATION

UTILITIES ENGINEERING

WATER RESOURCES/
STORMWATER MANAGEMENT

GRAPHICS & VISUALIZATION

 
   

Facebook DRMP Google + DRMP LinkedIn DRMP Twitter DRMP You Tube DRMP
© 2016 DRMP, Inc. I Site Map    
DRMP Home